Factory-direct WDZN halogen-free low-smoke fire resistant cable for metro, hospital and high-occupancy buildings

WDZN series combines a mica tape fire barrier with a halogen-free low-smoke sheath, so the circuit stays energised during a fire while releasing very little smoke and no corrosive acid gas. This matters in enclosed, high-occupancy spaces where smoke inhalation and equipment corrosion cause more damage than the flame itself — metro tunnels, hospital operating theatres, airport terminals and underground car parks. Available with XLPE insulation (WDZN-YJV / WDZN-YJY) or PVC insulation (WDZN-VV), 0.6/1 kV through 26/35 kV.

IEC/EN/BS/UL/CSAIEC 60332-3CB Test CertificateCCCISO 9001ISO 14001

Key features

  • Mica tape fire barrier over the conductor
  • Halogen-free low-smoke sheath — no corrosive acid gas when burning
  • XLPE (WDZN-YJV / WDZN-YJY) or PVC (WDZN-VV) insulation
  • Flame retardant to IEC 60332-3 grade A/B/C
  • Available 0.6/1 kV through 26/35 kV
  • Copper or aluminium conductor, class 1 / 2 / 5

Typical applications

  • Metro and rail tunnel emergency circuits
  • Hospital operating theatres and ICU distribution
  • Airport terminal and station concourse wiring
  • Underground car park and basement plant rooms
  • Data centre and control room supplies
  • Shopping centre and stadium distribution

WDZN-VV — 0.6/1 kV, Copper, Mica Tape + PVC, Five-Core, Unarmoured

Source: Huanghe factory technical data sheet (enquiry TDS “2026.04.23 0.6kV WDZN-VV”) — values as supplied

These figures come from a stamped factory data sheet, not from the printed catalogue. Mica barrier 0.14 mm (0.1 mm on 5×2.5). 70 °C conductor temperature — this is the PVC insulated build; see the XLPE table below for 90 °C.

Custom sizes available on request — send us your project specification.

Cores × Section (mm²)Overall Dia. (mm)Weight (kg/km)Current — In Ground (A)Current — In Air (A)Max. DC Resistance at 20 °C (Ω/km)
5×2.512.522535307.41
5×41531050404.61
5×616.441060503.08
5×1020.364080651.83
5×1623950100851.15
5×2527.314501301150.727
5×3529.918801551450.524
5×503225091851750.387
5×703635702252200.268
5×954048022702700.193
5×1204361623053150.153

WDZN-YJV — 0.6/1 kV, Copper, Mica Tape + XLPE, Solid Class 1 Conductor

Source: Huanghe factory technical data sheet (enquiry TDS “12.1 WDZN-YJV”) — values as supplied

Quoted against a solid class 1 conductor at the customer's request. Mica barrier 0.14 mm. Stranded class 2 gives different overall diameter — confirm conductor class on your order.

Cores × Section (mm²)Overall Dia. (mm)Weight (kg/km)Current — In Ground (A)Current — In Air (A)Max. DC Resistance at 20 °C (Ω/km)
2×1.58.675253012.1
3×1.5988253012.1
2×2.5911030357.41
3×41118340504.61

WDZN-YJV — 0.6/1 kV, Copper, Mica Tape + XLPE, Four-Core Plus Neutral

Source: Huanghe factory technical data sheet (enquiry TDS “7.24 WDZN-YJV 5+1类型”) — values as supplied

Cores × Section (mm²)Overall Dia. (mm)Weight (kg/km)Current — In Ground (A)Current — In Air (A)Max. DC Resistance at 20 °C (Ω/km)
4×80+1×5035.038002252200.215/0.387
4×100+1×7037.044502702700.183/0.268
4×240+1×12055.5106705004550.0754/0.153

WDZN-YJY23 — 0.6/1 kV, Copper, Mica Tape + XLPE, Steel Tape Armoured, LSZH Sheath

Source: Huanghe factory technical data sheet (enquiry TDS “9.30 0.6/1kV WDZN-YJY23”) — values as supplied

Single-core armoured build with halogen-free polyethylene outer sheath (23).

Cores × Section (mm²)Overall Dia. (mm)Weight (kg/km)Current — In Ground (A)Current — In Air (A)Max. DC Resistance at 20 °C (Ω/km)
1×12022.418103603350.153
1×24028.930305355350.0754

Need a voltage class, core count or sheath not listed above?

The WDZN range covers 0.5–1000 mm² at 0.6/1 kV and 35–1000 mm² for medium voltage (3.6/6, 6/10, 8.7/15, 12/20, 18/30, 26/35 kV), in 1, 2, 3, 4, 5, 3+1, 3+2 and 4+1 core builds, unarmoured / steel tape armoured (22) / steel wire armoured (32), with LSZH or PE sheath. Send us the cores, cross-section, voltage, armour type and destination port for a stamped data sheet.

LSZH Fire Resistant Cable (WDZN) gallery

LSZH Fire Resistant Cable (WDZN) sample
LSZH Fire Resistant Cable (WDZN) sample
LSZH Fire Resistant Cable (WDZN) sample
LSZH Fire Resistant Cable (WDZN) sample

Factory & delivery capability

Real photos from our production facility — from raw material to container loading.

Cable production line in China factory

Production Line

Quality testing laboratory for power cables

Quality Testing

Cable warehouse with finished products on wooden drums

Warehouse & Stock

Cable drum packaging ready for container loading

Drum Packaging

Cable drums loaded into shipping container for export

Container Loading

Completed shipment of power cables in 40ft container

Ready to Ship

Frequently asked questions about LSZH Fire Resistant Cable (WDZN)

Q.What does WDZN stand for?

It is a stacked Chinese type code: WD is halogen-free (无卤), Z is flame retardant (阻燃), N is fire resistant (耐火). So WDZN-YJV is a halogen-free, flame retardant, fire resistant XLPE cable. WDZ without the N is halogen-free flame retardant only — it limits flame spread but does not keep the circuit alive.

Q.What is the difference between WDZN-VV and WDZN-YJV?

Insulation. VV is PVC insulated with a 70 °C conductor rating; YJV is XLPE insulated with a 90 °C rating, so it carries more current at the same cross-section. Both use the same mica tape fire barrier and halogen-free sheath.

Q.Is LSZH the same as fire resistant?

No, and they are often confused. LSZH describes what the sheath emits when it burns — little smoke, no halogen acid gas. Fire resistant (the N in WDZN) describes whether the circuit keeps working during the fire, which comes from the mica tape barrier. A cable can be LSZH without being fire resistant, and vice versa.

Q.Do you supply medium voltage LSZH fire resistant cable?

Yes. WDZN-YJY and WDZN-YJLY cover 3.6/6, 6/10, 8.7/15, 12/20, 18/30 and 26/35 kV in 35–1000 mm², single-core and three-core, with copper tape screen and optional armour. Send your voltage and cross-section for a data sheet.

Q.What are the MOQ and lead time?

MOQ is 500-1,000 metres per size for standard constructions, or 2,000-5,000 metres for custom specifications. Lead time is 10-15 days depending on drum quantity and stock. LSZH compound is made to order for larger volumes, so send your cable schedule early for a firm date.

Q.What packaging do you use for export?

Wooden drums for export, marked with cable type, cross-section, length and your shipping marks. Typical drum lengths are 100 m, 200 m, 500 m or 1000 m.

Related Technical Guides

Learn more about LSZH Fire Resistant Cable (WDZN) specifications, installation, and sourcing.

Ready to source LSZH Fire Resistant Cable (WDZN) from the factory?

Send your specs — voltage rating / conductor size / cores / armour / length / destination port. Quote within 24 hours.